Commercial Septic System Operation and Maintenance
For some commercial establishments, the sources and characteristics of wastewater
may be quite similar to those of residential wastewater. For other businesses and
institutions, however, wastewater may be very different: for example, it may contain
harsh industrial-
Fats, Oils and Grease
The most serious problem that plagues commercial septic systems
is the carry-
The drainfield of a well-
For this reason, many states
require the use of grease traps (also called grease interceptors) by restaurants
and similar commercial establishments. Grease traps are holding tanks, often modified
septic tanks, that receive kitchen wastewater prior to the passage of that wastewater
to the main septic tank. Other non-
Traditionally, grease
traps have been used in a range of commercial establishments, including garages,
automotive facilities and other commercial/industrial situations. Grease traps at
these facilities are being phased out, with zero discharge becoming the standard
by 2003. Septic systems may be used for domestic or toilet wastewater at these establishments,
but not for wastewater generated by automotive/industrial processes. (Under EPA guidelines,
this wastewater must be collected separately and disposed/recycled off-
Location of grease traps is mandated by local ordinances.
Typically, these traps are located as close to the source of the FOG as possible.
Grease traps generally range in size from one to three times the average daily flow
that will be discharged into it. For example, a restaurant serving 100 customers
daily who contribute 10 gallons per day of kitchen wastewater will require a grease
trap that is between 1,000 to 3,000 gallons. As with the main septic tank, proper
sizing of the grease trap is critical to its ability to fulfill its function.
Good Operation and Maintenance
Good operation and maintenance practices enable the
grease trap and septic tank to work effectively in reducing grease and oil. Restaurants
and other establishments should scrape food scraps and congealed fats into the garbage,
use drain covers and sink baskets and strainers to prevent solids from entering the
flow of wastewater and eliminate, or at least limit, the use of a garbage disposal.
Cooking oil and grease should never be poured down the drain. Finally, commercially
available septic system additives that claim to reduce oils and grease should not
be used. Although these additives do indeed dissolve oils and grease, this only increases
the likelihood that these materials will be carried over to the drainfield rather
than remaining in the grease trap and septic tank where they can be slowly broken
down and pumped out at regular intervals. Carried-
A note about dishwashers and grease traps:
some experts recommend that wastewater from dishwashers not be discharged into the
grease trap but rather flow directly into the septic tank. This is because the high
rate of flow and high temperature of the dishwasher wastewater can cause excessive
turbulence in the grease trap (usually smaller in size than the septic tank) and
emulsify FOG, resulting in carry-
Perhaps
above all else, the key to the effectiveness of the grease trap is regular, frequent
pumping. Depending on the size of the grease trap and the strength and flow of wastewater
at a given commercial establishment, required pumping frequency may range from twice
per month to once every three or six months. A proper pumping does not just remove
the liquid in the grease trap but scours the grease trap and the associated lines
to eliminate caked-
Tank Pumping Frequency
As with residential systems, regular, scheduled pumping of
the septic tank is arguably the most essential element of commercial septic system
maintenance. The important difference lies in the frequency of pumping: commercial
septic tanks typically require (much) more frequent pumping than their residential
counterparts.
There are several reasons for this:
Faster rate of wastewater flow, resulting in greater likelihood of solids carry-
Greater strength of wastewater (higher "organic load," that is, higher concentrations of solids and fats, oils and grease), resulting in faster accumulation of solids in septic tank
Presence of harsh cleaners and other chemicals not normally found in household wastewater, potentially resulting in harm to bacteria that breakdown wastewater in the septic tank
Varied and changeable group of system users (employees and customers), resulting in somewhat lessened ability to control/enforce good maintenance practices (as compared to household)
How frequently you will need to have your particular tank pumped depends on a number of factors, including:
Type and size of your establishment
Size of your septic tank
Volume and rate of wastewater flows
Amount of organic matter (e.g., waste solids, food scraps, fats/oils/grease) in your establishment's wastewater
The first two factors are essentially fixed. If, however, your septic tank is undersized,
you may need to replace it with a larger tank to improve the quality of wastewater
treatment. The second two factors can be significantly influenced by your operational
practices.
Here are some things you can do to avoid overstressing your septic system
over the long term and using pumping (which will always be necessary, whatever your
maintenance habits) as a substitute for good operational basics:
In restrooms: make sure plumbing fixtures don't leak; install automatic shut-
In kitchens: divert kitchen wastewater to grease trap; scrape plates into the garbage,
not the sink; install drain covers and sink baskets/strainers to prevent solids (food
scraps, FOG) from entering your system; avoid use of garbage disposal; use water-
In laundry facilities: avoid use of harsh detergents; space out laundry over the course of the week rather than doing establishment's washing all at once
An inspection of your septic system by a licensed septic inspector (which should
be an annual event) can help you determine the pumping frequency your tank requires.
You should schedule pumping with a licensed pumper based on your required frequency
(e.g., every three months, twice a year). This same pumper may also be able to pump
out your grease trap. Note, however, that grease traps will almost always require
more frequent pumping than your septic tank to function effectively. Pumping generally
costs $200-
The bottom line for commercial
septic systems is: have a knowledgeable septic professional determine how frequently
your tank and grease trap requires pumping, set a maintenance schedule based on that
and stick to it!
Septic tank risers
An important part of septic system maintenance, inspection and pumping must be performed through the septic tank inspection ports and service lids. An effective method of providing proper access is through the installation of septic tank access risers. This allows the maintenance professional to access the lids on the tank without having to unearth them each time the system needs service. The installation of risers can usually be completed in one or two hours. Most pumpers offer this service.
Septic Tank Effluent Filter
A filter placed at the outlet of the septic tank to trap suspended solids that are not heavy enough or had had insufficient time to sink to the bottom of the tank. Effluent filters must be periodically cleaned (e.g., when tank is pumped out) so that they do not clog up and back effluent into the house. Effluent filters come in many shapes and sizes, a licensed service provider can determine which filter is best suited for your system.